The BIOPURE 200/300/600 reduces the contamination risk to patients by feeding high purity water at the point of use to large automated washer disinfectors and endoscope reprocessors.
Overview
It is specifically designed for sterile services/decontamination and endoscopy and is ideal for preventing the depositions commonly associated with using mains water to rinse endoscopes and automated endoscope reprocessors (AER).
The compact cabinet-style system can generate flows of 200, 300 or 600 litres of biopure water every hour and integrates easily with multiple washers from a wide variety of manufacturers, offering a unique opportunity for medical facilities to future-proof their washer systems.
Features and Benefits
The BIOPURE 200/300/600 cost-effectively provides biopure water at rates of 200 to 600 litres/hr.
Features |
Benefits |
---|---|
Integral Class "A" Air Break-tank on feedwater supply |
To comply with local by-laws and save space |
High efficiency Reverse Osmosis membrane |
For broad removal of organic/inorganics |
Integral 350 litre biopure water reservoir with bacterial vent filter to maintain microbiological integrity and spay ball return to ensure full coverage of internal surfaces |
To prevent biofilm build up |
Variable speed recirculation pump |
To provide instantaneous delivery flow whilst minimising temperature gain and noise levels |
Ultra-violet steriliser |
For continual bacteria destruction and maintenance of low microbiological levels |
Ultrafiltration membrane |
Providing final security against microbiological and particulate contamination |
Integrated self-disinfection facility |
To maintain the system in a hygienic state |
Comprehensive monitoring and control system |
To support validation and protect downstream processes by inhibiting bacterial growth opportunities |
Hygienic sample point |
To ensure reliable and consistent off line water quality monitoring |
Small footprint (Depth and Width) |
Maximises use of space |
Applications
- Sterile services
- Decontamination
- Endoscopy
Designed to meet:
- HTM 01-06
- NHS MES C32
- EN 15883
- MHRA/HIS Recommendations
Applications
Treated Water Specification
Model | Biopure 200 | Biopure 300 | Biopure 600 |
---|---|---|---|
Make-up rate | 200 l/h @ 15°C | 300 l/h @ 15°C | 600 l/h @ 15°C |
Delivery flow rate | 30 l/min @ 3.5 bar | 30 l/min @ 3.5 bar | 30 l/min @ 3.5 bar |
Inorganic | <30 µS/cm* | <30 µS/cm* | <30 µS/cm* |
Bacteria | <1cfu/10ml** | <1cfu/10ml** | <1cfu/10ml** |
Endotoxin | <0.25Eu/ml | <0.25Eu/ml | <0.25Eu/ml |
Particles | <0.05 micron | <0.05 micron | <0.05 micron |
*Subject to a maximum feedwater conductivity of <700µS/cm. For use outside this range please contact our technical department
**System to be regularly sanitized and installed following our installation design guidelines. Sample to be taken from hygienic sample valve and sampled in accordance with our guidelines.
Feedwater Requirements
Contaminant (Measure) | Range | Range | Range |
---|---|---|---|
Hardness (Total Hardness) (ppm as CaCO3) | <250 >250* | <10** >10** | <10** >10** |
Total Chlorine (CIppm) | <0.25 | <0.25 | <0.25 |
Silica (Sio2ppm) | <5 | <5 | <5 |
Fouling Index (FI) | <10 | <10 | <10 |
Iron/Manganese (Fe/Mn ppm) | <0.05 | <0.05 | <0.05 |
Temperature | Recommended 15-20°C | Recommended 15-20°C | Recommended 15-20°C |
Flow rate | 20 l/min | 20 l/min | 20 l/min |
Drain requirements Gravity fall with air gap, max during sanitization | 45 l/min | 45 l/min | 45 l/min |
Feedwater Pressure | 10bar (150psi) max 2 bar (30psi) min | 10bar (150psi) max 2 bar (30psi) min | 10bar (150psi) max 2 bar (30psi) min |
*Requires a softened water feed or an increase in the frequency of RO acid cleaning
**Requires a softened water feed as standard
Weights, Dimensions and installations
Height | 1820mm (71.7") | 1820mm (71.7") | 1820mm (71.7") |
---|---|---|---|
Width | 730mm (28.75") | 730mm (28.75") | 756mm (29.76") |
Depth | 890mm (35") | 890mm (35") | 1100mm (43.31") |
Supply Weight | 180kg (396lb) | 180kg (396lb) | 210kg (463lb) |
Operational Weight | 210kg (463lb) | 210kg (463lb) | 560kg (1,235lb) |
Installation | Floor mounted | Floor mounted | Floor mounted |
Electrical Requirements
Mains Input | 230V ac, 50Hz | 230V ac, 50Hz | 230V ac, 50Hz |
---|---|---|---|
Systems control voltage (not including pumps and UV) | 24V dc | 24V dc | 24V dc |
Power consumption (peak demand) | 2200VA | 2200VA | 2200VA |
Electrical protection rating | 20amps | 20amps | 20amps |
Noise level during recirculation | <60dBA | <60dBA | <60dBA |
Self-Disinfection Program
Designed for ease of use by hospital staff, the Biopure incorporates a novel new disinfection system:
- Accessed by secure E-Key control interface
- Intelligent recognition of disinfectant concentration at start of cycle and during exposure phase and final rinse-out
- Complementary Ultrafiltration, disinfectant and test strips to provide complete validation assurance
- Ease of use
- No removal of filters or disabling of UV lamp
- Fully automated monitoring and control
- User defined disinfection reminders